CONTACT US      email    |   07 3823 1922 

BioTrak 645i & 745i Thermal Mass Flow Meters by Sierra Instruments

Sierra Instruments BioTrak 645i 745i Thermal Mass Flow MeterBioTrak 645i & 745i Thermal Mass Flow Meters - Wastewater Dedicated Thermal Insertion/Inline Flow Meter

 

The Sierra Instruments BioTrak Thermal Mass Flow Meters meet the rugged demands of municipal and industrial wastewater plants where aeration, digestion, and cogeneration play pivotal roles. The BioTrak has been designed and manufactured to be the best-performing thermal mass flow meter in the wastewater industry. It makes operators smarter and their processes more reliably efficient. BioTrak is created specifically for plant engineers focused on renewable wastewater processes where healthy microbial growth is crucial. It provides the precise measurements and control required to optimize aerobic and anaerobic treatment and produce biogas. 


BioTrak
TM 645i/745i
 
  • Field-Selectable Gases-air, methane, digester gas
  • Direct mass flow measurement maintains precise control of aeration, digestion, and cogeneration
  • Air: +/-1% of reading +/-0.2% of full scale  - Other gases: +/-1.5% of reading +/-0.5% full scale
  • Insertion and inline versions
  • AC or DC power input available
  • Optional hot top packing gland and retractor
  • Integral and remote electronic configurations are available
  • Wide measurement range up to 1000:1 turndown; 100:1 typical
  • BioCal Calibration Validation within five minutes  

 

This email address is being protected from spambots. You need JavaScript enabled to view it.

 

BioTrak 645i/745i Flow Meters - Simple. Fast. Effective.

With AC or DC power input, optional hot tap capability, and remote configuration, BioTrak is easy to install, operate and adjust in the field to avoid costly and time-consuming delays. Have a look at its digital platform: DigiSense, BioSelect, and BioView. They gather, preview, and deliver the data that supports your processes and meets regulations. Sierra BioTrak’s proven technology makes trust possible. And with reduced maintenance over the lifetime of the instrument, BioTrak significantly lowers cost. Fast and Flexible, BioTrak offers the flexibility to monitor multiple gas types at the push of a button, rotate the housing as needed for tight installations, and configure meter settings from advanced software. Both AC and DC power inputs are available. 

BioTrak 645i Insertion flow meter / 745i Inline flow meter

The BioTrak is available in insertion (645i) and inline (745i) models and in a remote version with a junction box and cable. A USB port to connect to a computer or laptop is standard for insertion and inline configurations; interface options include HART or Modbus RTU (RS485). 

BioTrak 645i Insertion 745i Inline dedicated flow meter

Digital Platform 

How the BioTrak Thermal Mass Flow Meters Work

The BioTrak measures the gas flow rate in standard units without the need for temperature or pressure compensation. It provides two galvanically isolated 4-20mA analog outputs, HART communication (optional), a pulse output, switch input, and Modbus RTU (RS485) (optional). 

Sierra’s BioTrak Thermal Mass Flow Meters use a constant temperature differential (constant ΔT) technology to measure the mass flow rate of gases. The thermal mass flow meters sensor consists of two Resistance Temperature Detectors (RTDs). The Reference RTD measures the gas temperature. Meanwhile, the instrument electronics heat the mass flow sensor, or heated element, to a constant temperature and measure the cooling effect of the gas flow. The electrical power required to maintain a constant temperature differential is directly proportional to the mass flow rate of the gas. 

DigiSense™ Sensor

DigiSense is the state-of-the-art sensor technology used in BioTrak. The thermal sensor interfaces directly with the BioTrak microprocessor for greater control, precision, and programmability. DigiSense accurately responds to changes in process variables (gas flow rate, pressure, and temperature) to determine mass flow rate, totalised flow, and temperature.

DigiSense’s correlation algorithms allow the meter to be calibrated on a single gas in the factory while enabling the user to select other gases in the BioSelect menu.

BioSelect™

To meet the monitoring needs of Process Engineers, BioSelect allows users rapid gas selection or digester gas mixing from a pre-calibrated list of gases, including air, methane, and digester gas mix in the field. With an optional on-board 2-line x 16-character backlit display, operators can view flow rate, total, elapsed time, process gas temperature, and alarms. The display is also used with the configuration panel to access flow meter settings, such as 4-20mA and pulse output scaling, pipe diameter, low flow cutoff, flow filtering (damping), display options, and high or low alarm limits.

BioView™

Sierra’s BioView advanced software is a free PC-compatible application available for download from Sierra’s website. Connect your Windows-based laptop or PC to the meter using the USB port interface to access meter data and configure the meter’s settings.

BioView Features

  • Quick access to all configuration parameters with pop-up windows and pull-down menus
  • Selection of measurement units, flow and temperature ranges, alarm settings, and more
  • Print or save a BioCal Calibration Validation Certificate
  • Set alarms; display alarm codes
  • Simulation mode used to align 4-20mA output with the input to the customer's PLC/DCS
  • Raw data to be viewed to diagnose or troubleshoot your meter
  • Data logging to an Excel® spreadsheet

 

Dedicated Accuracy

  • BioSelect™ menu provides field-selectable air, methane, and digester gas
  • Designed to deliver accurate flow measurement for aeration, digester, and cogeneration applications
  • Air: ±1% of reading ±0.2% of full scale
    Other gases: ±1.5% of reading ±0.5% full scale
  • AC or DC power input available
  • Optional hot tap packing gland and retractor
  • Integrated and remote electronic configurations
  • DigiSense™ robust sensor design
    • Sensing elements supported at both ends
    • Swivel probe +/-180° into four positions
  • Gross Heating Value and Density Calculations of Gas Mix
  • Measures gas flow rate in SCFM, MSCFD, KG/HR, and many more units
  • Wide measurement range up to 1000:1 turndown;100:1 typical
  • Negligible pressure drop
  • Provides two galvanically isolated 4-20mA analog outputs, HART communication (optional), a pulse output, switch input, and Modbus RTU (RS485) (optional)
  • Welded, 316 SS sensor construction
  • Stainless or carbon steel inline flow bodies optional
  • Low-end sensitivity for wastewater applications
  • FM (U.S.) and FMc (CANADA) approved for Class I,  Div 1; ATEX/IECEx approved for Zone 1
  • NEMA 4X and CE Mark

Field Flexibility

  • Microprocessor-based, field-programmable electronics
  • Standard on-board 2 line x 16 character,
  • backlit display with configuration panel
  • Free BioViewTM software is available
  • A USB port to connect to a PC is standard
  • BioCalTM calibration validation
  • NIST traceable calibration

Specifications for the BioTrak™ 645i/745i Thermal Mass Flow Meters

  • Measures air, methane, and digester gas to suit wastewater applications
  • Accuracy*: +/-2.0% of full scale
    *Accuracy specification applies to the customer's selected flow range
  • Repeatability: +/- 0.2% of the full scale 
  • Flow range 15 to 25,000 sfpm (0.07 to 120 nmps) 
  • Flow Response Time: 0.8 seconds (one-time constant)
  • Temperature Accuracy: +/-1ºF (+/-0.6ºC) 
  • Turndown 1000;1; 100:1 typical
  • Straight, unobstructed pipe requirement
    • 645S Insertion: 15 diameters upstream 10 downstream  
    • 745S Inline: 8 diameters upstream, 4 downstream
  • Temperature:
    • DigiSense™ sensor -40°C to 250°F (-40°C to 121°C)
    • Enclosure  -40°C to 158°F (-40°C to 70°C)*
      *NOTE: Display dims below -4°F (-20°C); function returns once temperature rises again.
  • Gas Pressure: Maximum gas pressure at 100°F
    Insertion: 740 psig (51 barg)
    Retractor: 150 psig (10.3 barg)
    *Note: When Teflon ferrule is ordered, gas pressure is 60 psig (4.1 barg) maximum
  • Input Power: 10-30 VDC 
  • One standard 4-20mA output proportional to mass flow rate; HART communication option
  • User-definable second channel: Option of pulse output or Serial Communication (Modbus RTU (RS485)
  • Welded, 316 SS sensor and flow body construction, carbon steel flow body optional
  • Digital communications:  HART and Modbus RTU
  • Hazardous-Area Location Enclosure NEMA 4X
  • USB connection standard
  • Factory calibration to NIST traceable standards
  • BioView™ Software to access all meter configuration & Data logging. 
  • Approvals:
    • FM (U.S.) and FMc (CANADA) approved for Class I, Div 1; ATEX/IECEx approved for Zone 1
    • CE

For more information download BioTrak 645i/745i  Dedicated Thermal Mass Flow Meters for wastewater applications by clicking on the link buttons below.

 

Download   the Sierra Instruments BioTrak 645i/745i Brochure

 

Download   the Sierra Instruments BioTrak 645i/745i datasheet

  • Flow Type: Gas Flow Meters