505-BC03 Frequency Input Batch Controller by Contrec

505 BC01 Dual Stage Batch Controller by Contrec

The Contrec 505 BC03 Batch Controller is a dual stage batch controller for reliable measurement of preset quantities using a mass frequency input. It can be used as a single or dual stage contoller and is suitable for fast batch applications providing the user with clear local readout and can be controlled via communications in more automated systems.

When access is authorised there is quick access to commonly used preset values directly from the front panel. Automatic overrun compensation caters for system delays such as valve closure for precise volumes.

The 505 BC03 instrument is compatible with a wide range of flowmeter frequency outputs, including millivolt signals, reed switches, Namur proximity switches and pulse trains via its smart front-panel program selection.

Features
Calculations
Specifications
Drawings
Downloads

505 BC03 Dual Stage Batch Controller features

  • Tailored for volumetric frequency flow input 
  • Single or Dual stage control
  • Quick access to common batch quantities
  • No-flow, leakage and overflow error detection
  • Remote RUN/STOP/RESET
  • Allows for non-linear correction
  • Storage of 100 transactions with time and date stamp
  • Selection of second language and user tags
  • Selectable protocols on serial ports including Modbus RTU and Printer output
  • Backlit display with LCD backup

Displayed Information

The front panel display shows the current values of the input variables and the results of the calculations. A list of the variables for this application and their type (total or rate) is shown at the end of this document.

The instrument can be supplied with a real-time clock for storage of up to 100 transactions with time and date stamps.

Communications

There are two communication ports available as follows:

  • RS-232 port
  • RS-485 port

The ports are available for remote data reading, printouts and for initial application loading of the instrument.

Retransmission & Control Outputs

The instrument can retransmit any main menu variable. The digital outputs can retransmit totals as pulses or operate as logic levels for control or error outputs. If the instrument has the advanced option, it outputs rates as a 4-20 mA signal.

Relay Outputs

The relay outputs 1 and 2 are used to control the flow of product for each delivery. These contacts are normally open and can be used to drive external relays, valves, pump circuits etc.

Software Configuration

The instrument can be further tailored to suit specific application needs including units of measurement, custom tags, second language or access levels. A distributor can configure these requirements before delivery. Instrument parameters including units of measurement can be programmed in the field, according to the user access levels assigned to parameters by the distributor.

All set-up parameters, totals and logged data are stored in non-volatile memory with at least 30 years retention.

Calculations for the 505 BC03 Batch Controller

The total and flowrate are derived from accurately measured frequency and the number of received pulses.

volume = pulses / k-factor

volume flow = frequency / k-factor

Automatic overrun compensation calculates the new valve closure point to ensure correct delivery by averaging the overrun amount from the last three complete batches.

The overrun compensation value is valid for a new preset value provided the stored overrun is less than 20% of the new preset.

505 BC03 Specifications

Operating Environment Temperature
0°c to +60°c (conforma coating)
+5°c to +40°c (no coating)
Humidity
0 to 95% non condensing (conformal coating)
5% to 85% non condensing (no coating)
Power Supply

95 - 135V AC or 190 - 260V AC    or   12 - 28V DC

Consumption 6W (typical)
Protection SEaled to IP65 (Nema 4X) when panel mounted
Dimensions 147mm (w) X 74mm (h) X 167mm (d)
Display      Type Backlit LCD with 7 digit numeric display and 11 character alphanumeric display
Digits 15.5mm high
Characters 6mm high
LDC Backup Last data visible for 15 minutes after power down
Update Rate 0.3 second
Non-volatile Memory  Rentention > 30 years
Data Stored Setup, Totals and Logs
Approvals  Interface CE compliance
Data Stored IECEx, ATEX and CSA approved enclosures available for hazardous area
Real Time Clock (optional) Battery Type 3 volts lithium button cell (CR2032)
Battery Life 5 years (typical)
Fequency Input (general) Range 0 to 10kHz
Overvoltage 30V maximum
Update Time 0.3 seconds
Cutoff Frequency Programmable
Configuration Pulse, coil or NPS input
Non-linearity Up to 10 correction points
Pulse Signal Type CMOS, TTL, open collector, reed switch
Thershold 1.3 volts
Coil Signal Type Turbine and sine wave
Sensitivity 15mV p-p minimum
NPS Signal Type NPS sensor to Namur standard
Remote Logic Inputs Signal Type Voltage free contact, open collector
Relay Output No. of Outputs 2 relays
Voltage 250 volts, AC, 30 volts DC maximum
Current 3A maximum
Communication Ports Ports
RS-232 port
RS-485 port
Baud Rate 2400 to 19200 baud
Parity Odd, even or none
Stop Bits 1 or 2
Data Bits 8
Protocols Modbus, RTU, Printer*
Transducer Supply Voltage 8 to 24 volts DC, programmable
Current 70mA @ 24V, 120mA @ 12V maximum
Protection Power limited output
Pulse/Digital Output Signal Type Open collector, non-isolated
Switching 200mA, 30 volts DC maximum
Saturation 0.8 volts maximum
Pulse Width Programmable: 10, 20, 50, 100, 200 or 500ms
4-20mA Output (optional) Supply 24 volts DC internal, non-isolated
Resolution 0.05% full scale
Accuracy
0.05% full scale (20°c)
0.1% (full temperature range, typical)
Important: Specifications are subject to change without notice
*Printer protocoal is available only if RTC option is installed. 